Connecting the Control Unit to the Network Interface
Page 4-17
Installing the Channel Service Unit
The ACCULINK front panels include an LCD display and 7-button
keypads composed of three functional and four directional keys.
They contain integral 2400-bps modems for remote access and
alarm reporting.
The front-panel LEDs are labeled and colored differently from the
ESF T1 CSU.
The NETWORK connectors on the rear of the ACCULINK models
are 8-pin modular jacks (RJ48C) instead of male 15-pin
D-connectors. Cables are shipped with the units for the
CSU-to-Smart Jack connection.
There are no DIP switch options. All options are set via software
commands. Access the options in the following ways:
Locally, from the front panel
Remotely, using the integral 2400-bps modem. The front
panel of a local ACCULINK, in Passthrough mode, can
access and option a remote CSU
Locally and remotely, through the COMPORT connector on
the rear and a PC loaded with a Windows
software
package (available at an extra charge from Paradyne)
NOTE:
If you are upgrading to Release 6.0 or 6.1, make sure the
CSU is programmed for PRI signalling at either end of a PRI
tandem trunk. You may have an existing setting for T1 or
robbed-bit signaling rather than PRI signaling. If the CSU is
not set for PRI signalling, you will get an error message,
“PRI D-channel inoperative.”
The ACCULINK CSUs come equipped with two factory-set option
configurations: Factory 1 (Fact 1) and Factory 2 (Fact 2). They leave the
factory set at Fact 1. Two of the default parameters in Fact 1 are
ESF/B8ZS. In the Fact 2 setting, two of the default parameters are
D4/AMI.