Lucent Technologies 555-661-140 Telephone User Manual


 
MERLIN LEGEND Communications System Release 6.1
Installation
555-661-140
Issue 1
August 1998
Installing the Control Unit
Page 2-44
Connecting the Control Unit to an AC Outlet
Connecting the Control Unit to an
AC Outlet
!
CAUTION:
Make sure the AC outlet has been tested for proper grounding. The
outlet should be 117-V AC, 60-Hz, 3-wire (phase, neutral, ground).
See “AC Outlet Tests,” earlier in this chapter, for instructions.
To prevent someone from accidentally shutting off the power, do not
connect the control unit to a switch-controlled outlet. The AC outlet
should be within 5 ft. (152 cm) of the control unit.
To connect the control unit to a dedicated AC outlet, follow the steps
below.
!Turn the basic carrier’s power supply switch to the OFF position.
!Turn off the power supply switches on the expansion carriers.
!Unplug the power cords from any auxiliary power units.
!Plug one end of the power cord into the AC INPUT connector
located just below the power switch on the front of the basic
carrier’s power supply.
!Plug the other end of the power cord into the AC outlet, allowing at
least 1 ft. (30.4 cm) of slack in the cord.
!Repeat Steps 4 and 5 for each expansion carrier.
!
CAUTION:
Do not attach the power cord(s) to any building surfaces.