Lucent Technologies 555-661-140 Telephone User Manual


 
MERLIN LEGEND Communications System Release 6.1
Installation
555-661-140
Issue 1
August 1998
Installing Telephones and Adjuncts
Page 3-43
Installing Direct Station Selectors
Installing Direct Station Selectors
The Direct Station Selector (DSS) is an optional piece of telephone
equipment. You can connect up to two DSSs to an MLX-28D or
MLX-20L telephone that is programmed as an operator console.
Considerations
Review the following items before you begin the installation procedure.
Connect the DSSs before you assemble the MLX telephones.
Auxiliary power is required under the following circumstances:
An MLX telephone with an MFM and two DSSs requires a
406743419 power unit.
An MLX telephone without an MFM, but with two DSSs,
requires a 406943837 power unit, 400B adapter, and the
D6AP cord provided with the MFM.
An MLX telephone with one DSS and an MFM requires a
406943837 power unit, 400B adapter, and the D6AP cord
provided with the MFM.
If one carrier has three or more MLX telephones, each with
a DSS attached, use a 406943837 power unit, 400B
adapter, and D6AP cord for each MLX telephone and DSS
after the first two.
The total length of cords between the KS22911-L2 or 406743419
power supply and the MLX telephone must not be more than
50 ft. (15 m).
Do not replace the 2-ft. (61-cm) D8AC cord (packaged with the
DSS) with a longer cord. Improper operation may result.
Connect each KS22911-L2 power supply to an AC outlet that is
not controlled by a wall switch.