Lucent Technologies 555-661-140 Telephone User Manual


 
MERLIN LEGEND Communications System Release 6.1
Installation
555-661-140
Issue 1
August 1998
Installing Applications
Page 8-30
Installing a CTI Link
!Program the communications system.
At the Executive Station or using SPM, program the system in
Hybrid/PBX mode, busy out the slot, then program that MLX port as a
CTI link port. The functions for programming the system and the MLX
port are under the System Programming option. The functions to busy
out and restore the slot are under the Maintenance option. Be sure to
restore the slot after you finish the programming.
!Plug in the CTI link. Tag the cable and/or the port as the CTI link.
As a general rule, do not plug in a CTI link unless the port is
programmed as a CTI link port. Also, do not plug a telephone into a CTI
link port. The other end of this wire is plugged into the ISDN link
interface card installed in the NetWare server.
NOTE:
If you are installing an adjunct or an application into the CTI link, refer to
the books that come with that adjunct/application. Refer to the
System
Manager’s Guide
section “Adding a CTI Link” for detailed instructions.
Refer to the
MERLIN LEGEND Network Manager’s Guide
for
instructions. At this point the CTI link should be operational.
Link Reinstatement
The considerations and hardware requirements for a link reinstatement
are the same as those for a new installation since this procedure is used
only after a link shutdown.
A summary of the installation procedure for a link reinstatement is
provided below:
!Plug in the CTI link, if unplugged.
As a general rule, do not plug in a CTI link unless the port is
programmed as a CTI link port. Also, do not plug a telephone into a CTI