Installing Adjuncts
!To connect an adjunct to an analog multiline telephone:
a. Connect a 4-pair cord to the OTHER jack on the telephone.
b. Connect the other end to the VT jack on a General Purpose
Adapter (GPA).
c. Connect the cord from the adjunct to the TEL/EQUIP jack on the
GPA.
d. Go to Step 7.
Refer to “General Purpose Adapter” below for additional
information.
!Insert the other end of the adjunct cord directly into the port for the
logical ID on the 012 or 016 (T/R) module as indicated on the system
form. Go to Step 7.
!Test the adjunct by dialing its associated extension.
General Purpose Adapter
A General Purpose Adapter (GPA) lets you connect a T/R device—such
as a single-line telephone or modem—to an analog multiline telephone.
The device must be touch-tone, not rotary.
NOTE:
The GPA is intended for answer-only service, unless the telephone has
direct access to a line. It does not have touch-tone receivers or pulse dial
detectors; therefore, the associated analog multiline telephone must dial
calls.
The GPA cannot be used with a MERLIN II System Display Console.
When the system forms indicate a GPA for installation of an adjunct, follow
the steps below.
!Plug one end of a 4-pair adjunct D8AC cord into the VT jack on the
back of the GPA.
!Plug the other end into the OTHER jack on the underside of the
analog multiline telephone.
!Plug the cord from the adjunct into the TEL EQUIP jack on the GPA.