Installing the PC, CAT, or Printer
Page 5-5
Connecting a PC to the Control Unit
!
CAUTION:
If the PC is in a building outside the main building (control
unit location), you must install an ADU and an additional
protector in each building. The ADUs and protectors
provide both the control unit and the PC with additional
protection against lightning, inadvertent contact with power
lines, and power currents induced by nearby power lines.
For more information, see the installation notes packaged
with the ADU.
!Plug one end of a D8W cord into the WALL jack on the Z3A2 ADU
and connect the other end to an ADU crossover cable.
!Plug the other end of the ADU crossover cable into one of the jacks
on a 400B2 power adapter.
!Plug one end of a D6AP cord into the 400B2 power adapter.
!Plug the other end of the D6AP cord into a 2012D-50M transformer.
!Plug the 400B2 power adapter into a wall jack, BR1A-4P adapter,
102 connecting block, or 103 connecting block.
■ If you plug the 400B2 into a wall jack, make sure the building
wiring has been set up so that the wall jack near the control unit is
connected to the wall jack near the PC.
■ If you plug the 400B2 into a BR1A-4P adapter, 102 connecting
block, or 103 connecting block, use 4-pair plug-ended cable to
connect the BR1A-4P adapter (or connecting block) to the wall
jack near the PC.