Lucent Technologies 555-661-140 Telephone User Manual


 
Unit Load Calculation Worksheet
Page B-1
MERLIN LEGEND Communications System Release 6.1
Installation
Issue 1
August 1998
MERLIN LEGEND Communications System Release 6.1
Installation
555-661-140
Issue 1
August 1998
B
Unit Load Calculation
Wor ksh eet 2
If you determine that you need to recalculate the unit load for any carrier, use
the instructions on the following worksheet.
NOTE:
You should have a separate copy of the worksheet for each carrier.
See “Unit Loads” in Chapter 1 for information on recalculating unit loads.
The 391A3 power supply has a maximum rating of 75 unit loads. If your system
contains a 391A1 or 391A2 power supply module, and the unit loads for that
carrier will exceed 54, it is recommended that a 391A3 power supply be
installed in the system. Auxiliary Power Units cannot be used with the 391A3
power supply.