Lucent Technologies 555-661-140 Telephone User Manual


 
MERLIN LEGEND Communications System Release 6.1
Installation
555-661-140
Issue 1
August 1998
Installing Applications
Page 8-9
Call Accounting Terminal
Considerations
You can connect only one CAT to the system. You must use a serial
printer such as the CAT printer. You must locate the CAT Plus within the
distances noted below:
Control unit
14 ft. (4.27 m) direct connection
1000 ft. (305 m) using building wiring
Serial printer, 50 ft. (15.2 m)
Power supply-grounded wall outlet, 4 ft. (1.22 m)
Hardware Requirements
The following hardware is required for CAT installation:
Call Accounting Terminal, CAT Plus
Serial printer (Lucent Technologies CAT Printer is recommended)
connected by a Z200A EMI cable to the PRINTER jack of the CAT
D8W cord and 355AF adapter connecting the SMDR port on the
communications system to the SMDR jack of the CAT
A summary of the installation procedure is provided below:
!Before connecting the CAT, set the 10 CAT switches to establish the
speed or baud rate for the CAT and its associated printer.
!Connect the control unit, CAT, printer, and power supply. See
Chapter 5, “Connecting a Printer to the Control Unit.” Do not use an
outlet that is controlled by a wall switch.
!Test the CAT Plus, following the instructions provided in the
documentation packaged with the application.