Lucent Technologies 555-661-140 Telephone User Manual


 
MERLIN LEGEND Communications System Release 6.1
Installation
555-661-140
Issue 1
August 1998
Installing Applications
Page 8-16
Integrated Solution III
Message-waiting lights fail to light
CAS IS III uses the call information provided by the system’s built-in
SMDR feature to process calls.
SPM IS III reports can be printed out or can be written to a disk (hard or
floppy).
SPM IS III reports should not be printed while the system is handling
more than 100 calls per hour.
Only the CAS IS III and the SPM IS III applications can be connected to
a system operating in Behind Switch mode.
Hardware Requirements
The Master Controller II+ (Desktop) and the Master Controller III (Tower)
are the PC platforms for IS III. The Master Controller II+ is a desktop
20-MHz, 386-SX PC with three available AT bus slots (with the tape
drive installed). It has 8 MB of RAM memory, either a 100-MB or a
200-MB hard disk drive, 3.5-inch floppy drive, and a 125-MB streaming
tape drive.
The Master Controller III is a tower 20-MHz 486-SX PC with six
available EISA bus slots (with the tape drive installed). It has 8 MB of
RAM memory, either 200- or 500-MB hard disk drive, and a 250-MB
streaming tape drive.
The following hardware is also required:
A 355AF adapter for connecting the Master Controller to the serial
port on the control unit if they are within 50 ft. (15.2 m) of each
other and are on the same AC branch circuit
ADUs for connecting the Master Controller to the serial port on the
control unit, if they are not within 50 ft. (15.2 m) of each other
and/or they are not on the same AC branch circuit