Lucent Technologies 555-661-140 Telephone User Manual


 
MERLIN LEGEND Communications System Release 6.1
Installation
555-661-140
Issue 1
August 1998
Connecting Data Equipment
Page 6-12
MLX Voice and Terminal Adapter Data Stations
MLX Voice and Terminal Adapter
Data Stations
Figure 6–4 shows the equipment configuration for MLX voice and
terminal adapter data station.
The configuration shown in Figure 6–4 is for
asynchronous
terminal
adapter data transmission. For information on setting up
synchronous
terminal adapter data stations, see “Video Conferencing Data Stations,”
later in this chapter.
The maximum cord length from the terminal adapter to the telephone is
80 ft. (24.38 m).
Setting Up
To set up an MLX voice and terminal adapter data station, follow the
steps below:
!Use an EIA-232-D cable to connect the serial port on the data
terminal to the terminal adapter.
If the data terminal that has both COM1 and COM2 connectors, make
sure you use the one designated for data transmission. See the
customer’s system manager if you are not sure.
!Make sure the terminal adapter option settings for parity and speed
are compatible with the data terminal. (Speed is synchronized
automatically if the factory setting has not changed.)
If you are not sure about the speed and parity of the data terminal, see
the customer’s system manager or the documentation packaged with the
terminal adapter and data terminal.
!Plug the other end of the EIA-232-D cable into PORT 1 on the
terminal adapter.
!Plug the WP90110-L7 power supply cord into the POWER
receptacle on the terminal adapter.