AT&T 585-310-231 Telephone User Manual


 
Issue 2.0 December 1995 4-25
Two D8W-87 Modular Cords
M7-U87 Crossover Cable
Two Z3A2 ADUs
Two M8AJ-87 Cable
D8AM-87 Modular Crossover Cable
Two 400B2 Adapters
Two D6AP-87 Modular Cords
Two 248B Adapters
Two 2012D Power Transformers
NOTE:
The combination of a Z3A2 ADU and a M8AJ-87 cable is equivalent to a
Z3A4 ADU. You must order both pieces (one of each for Admin port,
another of each for SMDR port).
NOTE:
Inside wire must be 4-pair, suitable for data; type 3 UTP data cable or
better.
NOTE:
Local powering of the Z3A2 ADU is optional.
Connect to the first available port on the Multi-Port Serial Card.
Refer to Figure 4-13 Connect the terminal and the Intuity system by following
these steps:
1. Connect one end of the M7U-87 crossover cable to the terminal.
2. Connect the other end of the M7U-87 cable to the matching end of a
M8AJ-87 cable.
3. Connect the other end of the M8AJ-87 cable to the matching connector on
a Z3A2 ADU.
4. Connect one end of a D8W-87 modular cord to the modular jack marked
WALL on the Z3A2 ADU.
5. Connect the other end of the D8W-87 modular cord to the modular jack
end of a D8AM-87 crossover cord.
6. Connect the modular plug end of the D8AM-87 crossover cord to the
matching modular jack on a 400B2 adapter.
7. Plug the 400B2 adapter into the wall jack leading to the Intuity system site.
8. Connect one end of a D6AP-87 modular cord to the 400B2 adapter.