AT&T 585-310-231 Telephone User Manual


 
4-4 Issue 2.0 December 1995
Figure 4-1. Connecting IVC6 Boards Using 885A Adapter
Connect IVC6 Boards
Using 104A Connecting Blocks:
Connect IVC6 boards using type 104A connecting blocks as follows:
1. Make sure that the line pairs were run together to type 104A connecting
blocks or equivalent. (See Figure 4-2.)
2. Use the supplied D6AM 6-conductor modular cables between the IVC6
board and the type 104A connecting block.
NOTE:
This is one of many ways to connect IVC6 boards to the MERLIN LEGEND
system using inside building wire. It is subject to the same distance
limitations as stations. The key element is the connection of the T/R circuits
to the correct pins on the connecting block jacks.
885A Adapter
IVP6#
Lines
1-2-3
Lines
4-5-6
Line 1
EXT:
Line 2
EXT:
Line 3
EXT:
Line 4
EXT:
Line 5
EXT:
Line 6
EXT:
RJ11C
D2R-29
D6AM-87
D6AM-87
RJ11C
D2R-29
RJ11C
D2R-29
RJ11C
D2R-29
RJ11C
D2R-29
RJ11C
D2R-29
USOC
1 2 3
4 5 6
RJ25C
Line 1 Line 2 Line 3Line 4 Line 5 Line 6