4-14 Issue 2.0 December 1995
The following parts are required for connection to the Multi-Port Serical Card:
■ Multi-Port Serial Card (if needed and not already installed)
■ 6 position, 6 conductor straight-through modular cord (for connection to
Multi-Port Serial Card only, supplied with Multi-Port Serial Card)
■ DTE 4/6-to-DB-25P Adapter (for connection to Multi-Port Serial Card only,
supplied with Multi-Port Serial Card)
NOTE:
This adapter has slanted sides as shown in Figure 4-9.
The following parts are required for either type of connection:
■ 355AF Adapter
■ Z200A EMI Filter Modular Cord
■ Two D8W-87 Modular Cords
■ M7-U87 Crossover Cable
■ Two Z3A2 ADUs
■ Two M8AJ-87 Cable
■ D8AM-87 Modular Crossover Cable
■ Two 400B2 Adapters
■ Two D6AP-87 Modular Cords
■ Two 248B Adapters
■ Two 2012D Power Transformers
NOTE:
The combination of a Z3A2 ADU and a M8AJ-87 cable is equivalent to a
Z3A4 ADU. You must order both pieces (one of each for Admin port,
another of each for SMDR port).
NOTE:
Inside wire must be 4-pair, suitable for data; type 3 UTP data cable or
better.
Connect to Serial Port 2 (COM2) if it is available and if it is not reserved for use by
a Remote Maintenance Modem. If Serial Port 2 (COM2) is not available, connect
to the first available port on the Multi-Port Serial Card.
Refer to Figure 4-8. Connect the MERLIN LEGEND Communications System
SMDR port and the Intuity system by following these steps:
1. Connect the short end of the Z200A EMI filter modular cord to the SMDR
(upper) modular jack on the MERLIN LEGEND Communications System.
2. Connect the long end of the D8W-87 modular cord to a 355AF adapter.