Nortel Networks DCT1900 Telephone User Manual


 
Technical Product Manual - DCT1900
Product Specifications, Cables
Specs-DCT1900/R8/mw 9-1
© 2000-2005
CHAPTER 9
Cables
9.1 Cables for Modular Cabinet
Interconnection Set - NTMNB 101 105
To interconnect two adjacent Modular Cabinets.
Flat cable : Connects the backplanes, two 34–pin connectors
Shielding gaskets (4) : Connects the metal housing of the cabinets
Safety ground cable : Connects the ground of the cabinets
CLU/MDF Cable Set – NTM/TSRNB 101 29
This cable set consists of two similar cables. The only difference is the position of the shielding
clamp.
Cable length : 16.40 ft. (4.95m), 2 cables
Wires : 12 twisted pairs (each cable)
Connector CLU side : 32 pins, DIN41612 (each cable)
Connector MDF side : Amphenol 50 pin (contains hood and connection for 24AWG-
26AWG): Cable Diameter = .350 - .425
P/N: 1-229912-1 (mate plug)
Cable Diameter = .425 - .500
P/N: 3-22912-1
CLU/MDF Cable Set Long - NTM/TSRNB 101 46
Cable length : 82.02 ft. (24.78m), 2 cables
Wires : 12 twisted pairs (each cable)
Connector CLU side : 32 pins, DIN 41612
Connector MDF side : none
CLU/MCCB Power Cable – TSRNB 101 33
Cable length : 19.69 in. (500mm)
Wires : 2
Connector CLU side : 2 pins, Ericsson power connector
Connector MCCB side : 2 pins, MOLEX mini–fit, Jr
DTU/MCCB Cable – TSRNB 101 37
Cable length : 18.90 in. (480mm)
Wires : 2 coaxial pairs
Connector DTU side : 10 pins, DIN41612
Connector MCCB side : 10 pins, DIN41612
DTU/PBX Cable Set - NTM/TSRNB 101 49 (AWS1033)
Cable length : 49.21 ft. (14.87m), 2 cables
Wires : 2 twisted pairs (each cable)
Connector DTU side : 16 pins, DIN41612
Connector PBX side : 8 pins, DIN41612.