Nortel Networks DCT1900 Telephone User Manual


 
Technical Product Manual - DCT1900
Maintenance, Fault Finding Procedures
6-10
Maint-DCT1900/R8/mw
© 2000-2005
ERRORS
System List Error
Buzzer Data
Error
Fixed Phone
book Error
User Data Error
Initialization Error
END
No
No
No
No
No
Yes
Yes
Yes
Yes
Yes
Initialization data missing or
corrupted. Re-initialize Portable
Telphone.
Ringing cadence data missing
or corrupted. Re-initialize
Portable Telephone.
Fixed phone book data missing or
corrupted. If phone book was loaded, all
data is lost. Re-download phone book.
User data corrupted. All data (preferences) will be
replaced with defaults, speed dial numbers will be
cleared. This fault occurs only once; after cycling the
power the fault disappears, because defaults are set.
Error occured during initialization process.
Restart initialization.
1) For all faults correction actions are given.
If after correction a fault re-appears, the
Portable Telphone should be sent for repair.