Nortel Networks DCT1900 Telephone User Manual


 
Technical Product Manual - DCT1900
Installation Instructions, or BDVNB 101 01/3
Install-DCT1900/R8/mw 4-9
© 2000-2005
z Sync port installation set: NTMNB 101 107
-SDB
- Two spacers
- Two spring washers
z Torx screwdriver nr. 20
Follow the next steps for mounting the SDB:
1. Unscrew the left fixation screw of the mains switch bracket (refer to Figure 4–2 for the location
and orientation).
2. Insert a spacer in the left side screw hole and tighten the spacer using a Torx screwdriver.
3. Repeat steps 1 and 2 for the right side screw.
4. Mount the SDB as indicated in Figure 4–7 and tighten screws (maximum torque 0.59 lb./ft.).
Fig. 4–7 Mounting of the Synchronization Distribution Board
4.8 Mounting the Modular Cabinet(s) to the Wall
1. Hang the Modular Cabinet(s) up using the mounting bracket(s). In a multi cabinet
configuration, the cabinets must be placed against each other, so that the shielding gasket will
always make good contact with each other.
2. Secure the cabinet(s) to the wall by inserting and fastening the screws at the bottom of the
cabinet(s).
Bottom plate
Modular Cabinet
Spacer
SDB
Spring washer
Torx screw