4.14 Modular Cabinet Connection Board-MCCB (ROANB 101 28)
The MCCB provides connectors for a personal computer, a printer, 3 DTU E1 boards (coax
connections), Base Station powering, for 7 CLU boards or SLU boards, and a general alarm (via a
relay). The MCCB is located on the bottom plate of the Modular Cabinet.
4.15 Synchronization Distribution Board–SDB (REX-BRD0006 or ROANB 101 38)
The SDB allows the connection of one input and three output synchronization signals to the CPU
via 120 ohm shielded twisted pair cables. It is located on the bottom plate of the Modular Cabinet
near the MCCB. The synchronization signals are required to achieve PWT air interface