Table 4–3 Power Consumption (Watts) of Base Stations and Cabling when Powered with 42V
26 AWG (0.4 mm) wire size (
) 24 AWG (0.5 mm) wire size (
) 22 AWG (0.64 mm) wire size (
)
Cable
length
(Feet)
1 pair 2 pairs 3 pairs 1 pair 2 pairs 3 pairs 1 pair 2 pairs 3 pairs
0 7.5 7.5 7.5 7.5 7.5 7.5 7.5 7.5 7.5
82 8.8 8.6 8.6 8.7 8.6 8.6 8.6 8.6 8.5
164 9.1 8.8 8.7 8.9 8.7 8.6 8.7 8.6 8.6
246 9.5 9.0 8.8 9.1 8.8 8.7 8.9 8.7 8.6
328 10.0 9.1 8.9 9.4 8.9 8.8 9.0 8.7 8.7
410 10.7 9.3 9.0 9.7 9.0 8.8 9.2 8.8 8.7
492 11.6 9.5 9.1 10.0 9.1 8.9 9.3 8.9 8.7
574 13.1 9.8 9.3 10.5 9.3 9.0 9.5 8.9 8.8
656 - 10.0 9.4 10.9 9.4 9.1 9.7 9.0 8.8
738 - 10.3 9.5 11.6 9.5 9.1 9.9 9.1 8.9
820 - 10.7 9.7 12.5 9.7 9.2 10.1 9.2 8.9
902 - 11.1 9.9 14.0 9.9 9.3 10.3 9.2 9.0
984 - 11.6 10.0 - 10.0 9.4 10.6 9.3 9.0
1066 - 12.2 10.2 - 10.2 9.5 10.9 9.4 9.1
1148 - 13.1 10.5 - 10.5 9.6 11.3 9.5 9.1
1230 - 14.7 10.7 - 10.7 9.7 11.7 9.6 9.2
1312 - - 10.9 - 10.9 9.8 12.2 9.7 9.2
1476 - - 11.6 - 11.6 10.0 14.0 9.9 9.3
1640 - - 12.5 - 12.5 10.3 - 10.1 9.4
1804 - - 14.0 - 14.0 10.6 - 10.3 9.5
1968 - - - - - 10.9 - 10.6 9.7
2132 - - - - - 11.3 - 10.9 9.8
2296 - - - - - 11.8 - 11.3 9.9
2460 - - - - - 12.5 - 11.7 10.1
2624 - - - - - 13.3 - 12.2 10.2
2788 - - - - - 15.0 - 12.9 10.4
2952 - - - - - - - 14.0 10.6
3116 - - - - - - - - 10.8
3280 - - - - - - - - 11.0
3444 - - - - - - - - 11.3
3608 - - - - - - - - 11.6
3772 - - - - - - - - 11.9
3936 - - - - - - - - 12.2
4100 - - - - - - - - 12.7
4264 - - - - - - - - 13.2
4428 - - - - - - - - 14.0
4592 - - - - - - - - 15.4