6.10 Line Termination Unit, LTU - REX-BRD0007 or ROFNB 157 02/06
Compliance to Regulations and Standards
EIA-470 : USA
Environmental
Temperature
Operating : 32 to 158°F (0 to 70°C)
Storage : -40 to 158°F (-40 to 70°C)
Relative humidity : 20 to 80%, non condensing
General Specifications
Length x width 13.5" x 7.7" (343 x 195.6mm)
Telephone Line Interface Specifications
Insulation : 1.5 kVac between line and secondary circuitry
: 1 kVac between line and cabinet
DC Characteristics
Range of line current : 10-100mA
On–hook equivalent resistance : > 1M between wires a and b for 50 - 250 V
AC Characteristics
On–hook impedance : > 100 k for voice signals
> 15 k for ringing signal
Off–hook impedance : return loss optimized against 210 + (880 // 150 nF)
Ringing Detection
Ringing voltages : 10 - 90 Vrms
Frequency range : > 20 Hz
Pulse Dialing
Waveform : 60ms pulse, 40ms pulse-USA, Sweden
Selected digit N generates : N + 1 pulse or
N pulses and digit 0 generates 10 pulses
Resistance during pulsing : > 5 M and < 560
Line voltage : limited to 100 - 14Vdc
DTMF Dialling
The DTMF signals are determined by the combination of the SPU and the SICOFI parameters.
Speech Coding
Method : software selectable
AD Gain : determined by SICOFI parameters
DA Gain : determined by SICOFI parameters
Hybrid balance impedance : determined by SICOFI parameters