4.3 CONNECTING THE KX-TVS50/80 WITH THE PANASONIC KX-TD816, KX-TD1232 AND KX-TD308
72
INTEGRATING THE VPS WITH THE PANASONIC KX-TA ANALOG PBX AND KX-TD DIGITAL PBX
4.3 CONNECTING THE KX-TVS50/80 WITH THE
PANASONIC KX-TD816, KX-TD1232 AND KX-
TD308
Note
Do not use system programs [106] or [602] for DPT Integration. The following 2 Sections
(
4.3.1 KX-TD1232 Software Verification and Programming for Digital Integration via the
Manager's Extension
and
4.3.2 KX-TD1232 Software Verification and Programming for
Digital Integration via the Operating and Maintenance Tool
) are for the KX-TD1232 as
examples. Please refer to them for the KX-TD816
.
And the following Section (
4.3.3 KX-TD308 Software Verification and Programming for
Digital Integration via the Manager's Extension
) is for the KX-TD308
.
4.3.1 KX-TD1232 Software Verification and Programming for
Digital Integration via the Manager's Extension
It is important that the KX-TD1232 has the proper software level to allow Digital Integration
with the VPS. Follow the procedures below to confirm the software level, then complete the
required programming before starting up the VPS.
Note
Two methods of programming are available on the KX-TD1232. The instructions below
show how to program without the operating and maintenance tool. For instructions on
programming with the operating and maintenance tool, please see
4.3.2 KX-TD1232
Software Verification and Programming for Digital Integration via the Operating and
Maintenance Tool.
All of the following procedures must be done after entering system programming. Refer
to the KX-TD1232 Installation Manual for instructions on how to enter the system
programming mode.
Software Verification
1.
Verify Software - If you are configuring a 2-cabinet system, remember to check both
cabinets. The software must be the same in each. Check the software version of the KX-
TD1232 using System Program [116].
Example:
P231UYMMDD
A
The underlined digits represent the software production date code (year, month, day). For
Digital Integration, the software version of the PBX must be P231U or higher.
(For KX-TD816, the version must be version P301O or higher for Digital Integration to be
utilized.)
If the software version of the PBX is lower than this, call National Parts Center (1-800-