3.3 CONNECTING THE VPS WITH PANASONIC KX-T SERIES PBXs
INTEGRATING THE VPS WITH PANASONIC KX-T PHONE SYSTEMS
51
3.3.2 KX-T123211D Software Verification and Programming for
Inband Integration
1.
Check the software version of the KX-T123211D by using System Program [98], which
shows the software version number:
Y201Z940430
(TM3)
The underlined digits represent the software production date code (format YYMMDD). In
this example, the date code is April 30, 1994 (year, month, day). For this software version,
the software production date of the PBX must be April 30, 1994, or later.
If the software production date of the PBX is earlier than 4/30/94, call National Parts
Center (1-800-833-9626) to order a software upgrade.
2.
Enable System Program [80] for each extension connected to the VPS.
This parameter is used to tell the KX-T123211D which extensions are connected to the
VPS. Ports with this parameter enabled can receive Follow-on ID and DTMF call status
signaling (busy, answered, disconnect, etc.) if the Voice Mail integration and DTMF
integration features are also enabled.
3.
Enable System Program [81] to turn on DTMF Integration. On extensions with the Voice
Mail port parameter enabled, the KX-T123211D can send codes (DTMF tones) to indicate
call states; this increases VPS efficiency. Codes apply to all transferred calls; CO line calls
only indicate disconnect (provided the KX-T123211D is programmed for CPC detection
and the CO sends the CPC signal). Refer to the Table 11 in the Section 3.2.4 PBX
Interface Parameters.
4.
Put all extensions connected to the VPS into 1 extension group using System Program [60].
Reserve this extension group for these extensions! Do not mix other extensions into this
group.
Release Sequence
for Call Waiting
*N/AFN/AN/AFFF
* Check with manufacturer.
N/A Not Available
(A) Adding "A" for "answer" to the operator and extension transfer eliminates the message:
"You have a call" when the AA transfers a call. The VPS disconnects after line is
answered. Adding "D" for "disconnect" creates a blind transfer.
Table 12
PBX Type Other
Manufacturers
T308/
T616
T1232 T96 T336 TD816/
1232
TD308 TA series