Cisco Systems SPA232D Telephone Accessories User Manual


 
Administration Settings
Reboot
Cisco SPA232D Administration Guide 196
5
STEP 1 Click Browse to locate the .cfg file on your computer.
STEP 2 Click Restore to restore the settings from the selected file.
Reboot
Use the Administration > Reboot page to power cycle the ATA (if necessary) from
the configuration utility. Alternatively, accomplish this task by pressing the RESET
button.
To open this page: Click Administration in the menu bar, and then click Reboot in
the navigation tree.
Click the Reboot button to power cycle the ATA. When the warning message
appears, read the information, and then click OK to reboot the ATA, or click Cancel
to abandon the operation. The ATA and any connected devices will lose network
connectivity during this operation.
NOTE To avoid reboot upon every resync (when a same parameter appears in multiple
profile files), the changed parameters are saved in a temporary table and applied
to flash after processing all the profile files.
For example:
—profile A : <_Proxy_1_>1.1.1.1<_Proxy_1_>
—profile B: <_Proxy_1_>2.2.2.2<_Proxy_1_>
After all the profile files are processed, Proxy_1 parameter in the flash is saved
with 2.2.2.2 and then reboot once. ( Proxy_1 from profile A is overwritten and takes
no effect.)
Save the parameter to the table if it is not in the table or is different with current
flash value, otherwise remove from the table.