Cisco Systems 7912G IP Phone User Manual


 
8-33
Cisco IP Phone Models 7905G and 7912G Administrator Guide (SIP)
OL-4277-01
Chapter 8 Profile and Web Page Parameters and Defaults
Parameter Details
ReorderTone Parameter Example1
Assume that you want a reorder tone in which:
The frequencies 900 Hz, 1400 Hz, and 1800 Hz play sequentially.
Each frequency plays once for 0.33 seconds.
There is no silence after the first and the second frequencies.
There is 1 second of silence after the third frequency (before the first
frequency starts again)
The volume of each frequency is –19 dBm.
The tone plays until another call event stops the tone.
For this reorder tone, make the following setting. See Table 8-7 for a detailed
explanation.
ReorderTone:1,3,24917,3405,14876,4671,5126,5178,3,2640,0,2640,0,
2640,8000,0,0
Table 8-7 Reorder Tone Parameter Example 1 Explanation
Component Setting Explanation
Sequential 1 Frequencies play sequentially
NumOfFreqs 3 Three frequencies in the tone
TFreq_1 24917 First frequency is 900 Hz
TAmplitude_1 3405 First frequency volume is –19 dBm
TFreq_2 14876 Second frequency is 1400 Hz
TAmplitude_2 4671 Second frequency volume is –19 dBm
TFreq_3 5126 Third frequency is 1800 Hz
TAmplitude_3 5178 Third frequency volume is –19 dBm
NumOfOnOffPairs 3 Three on-off pairs in the cadence of the tone
OnTime_1 2640 Sound in first on-off pair plays for 0.33
seconds
OffTime_1 0 No silence after the first sound (the second
sound plays immediately)
OnTime_2 2640 Sound in second on-off pair plays for 0.33
seconds