Cisco Systems 7912G IP Phone User Manual


 
Chapter 8 Profile and Web Page Parameters and Defaults
Parameter Details
8-30
Cisco IP Phone Models 7905G and 7912G Administrator Guide (SIP)
OL-4277-01
Figure 8-1 Cadence with Two On-Off Pairs
TotalToneTime is the total length of time that the tone plays. If this value is 0,
the tone will play until another call event stops the tone.
For the BusyTone, DialTone, DialTone 2, and RingBackTone parameters,
specify this value in 10 ms units (100 ms = 1 second). For the CallWaitTone
parameter, specify this value as a number of samples with the sampling rate
of 8 kHz.
ReorderTone Parameter Details
The ReorderTone parameter specifies the tone that plays when the called number
is not available or the external circuit is busy. This tone can consist of either
Up to three frequencies played simultaneously and a cadence of up to three
on-off pairs. The first on-off pair can repeat multiple times before the second
on-off pair plays.
For example, a 400 Hz frequency plays four times for 0.75 second followed
by 0.1 second of silence after each play and then plays one time for 0.75
second followed by 0.4 second of silence. This pattern can be set to repeat
until another call event stops it.
Up to three frequencies played sequentially with a cadence of up to three
on-off pairs
For example, the frequencies 900 Hz, 1400 Hz, and 1800 Hz play sequentially
for 0.33 seconds each with no silence after the first and second frequencies
but 1 second of silence after the third frequency.
For the default value of this parameter, which is suitable for the United States, see
Table 8-4.
OnTime_1
OffTime_1
OnTime_2
OffTime_2
Sound
Silence
99267