NumOfOnOffPairs is the number of on-off pairs in the cadences of the tone
(0, 1, 2, or 3). For a steady tone, use 0.
If this value is 0, the OnTime_1, OnTime_2, OnTime_ 3, OffTime_1,
OffTime_2, and OffTime_3 values must also be 0.
OnTime_1, OnTime_2, and OnTime_3 are the lengths of time that the first,
second, and third on-off pairs of a cadence play a sound, respectively. (See
Figure 8-2 for a graphical representation.)
Specify each value as a number of samples with the sampling rate of 8 kHz.
The range of each value is 0 to 0xffff.
For example, for a length of 0.3 seconds, set a value to 2400.
OffTime_1, OffTime_2, and OffTime_3 are the lengths of silence after the
sound of the first, second, and third on-off pairs of a cadence, respectively.
Specify each value as a number of samples with the sampling rate of 8 kHz.
The range of each value is 0 to 0xffff.
For example, for a length of 0.3 seconds, set a value to 2400. (See Figure 8-2
for a graphical representation.)
Figure 8-2 Cadence with Three On-Off Pairs
NumOfRepeats is the number of times that the first on-off pair of the cadence
(specified by OnTime_1, OffTime_1) repeats before the second on-off pair
(specified by OnTime_2, OffTime_2) plays.
For example, if NumOfRepeats is 2, the first on-off pair will play three times
(it will play once and then repeat two times), then the second on-off pair will
play.
TotalToneTime is the total length of time that the tone plays. If this value is 0,
the tone will play until another call event stops the tone.
This value is in 10 ms units (100 ms = 1 second).
OnTime_3
OffTime_3
99267
OnTime_1
OffTime_1
OnTime_2
OffTime_2
Sound