Cisco Systems 7912G IP Phone User Manual


 
Chapter 8 Profile and Web Page Parameters and Defaults
Tone Parameters
8-22
Cisco IP Phone Models 7905G and 7912G Administrator Guide (SIP)
OL-4277-01
Table 8-4 Tone Parameters
Parameter Description
SigTimer Timeout values for signal events.
Bits 0–7: CWT Period, which the number of 0.1-second intervals to wait
between each burst of call-waiting tone. The range is 0 to 255. The default
value is 100 (0x64, 10 seconds). 0=Use default.
Bits 8–13: Reserved.
Bits 14–19: Ring Timeout, which is the number of 10-second intervals to
wait between when the phone starts ringing and the phone rejects the
incoming call. Range: 0 to 63. 0=Never time out. Default value: 6 (0x6,
60 seconds).
Bits 20–25: NoAns Timeout, which is the number of seconds to wait
between when the phone starts ringing and the phone initiates call
forwarding on no answer. Range: 0 to 63. Default value: 20 (0x14,
20 seconds).
Bits 28–29: First Key Repeat Interval, which specifies how long a user
must hold the Volume or the Navigation button up or down before the
desired change begins to repeat. Valid values: 0 (1 second), 1 (disable
repeat), 2 (2 seconds), and 3 (3 seconds). Default value: 0 (1 second).
Bits 30–31: Subsequent Key Repeat Interval, which specifies the intervals
at which a change continues to repeat (after the First Key Repeat Interval)
when a user continues to hold the Volume or the Navigation button up or
down. Valid values: 0 (0.25 second), 1 (0.5 second), 2 (0.75 second), and
3 (1 second). Default value: 0 (0.25 second).
Value type: Bitmap.
Default value: 0x01418064