Polycom VSX Series Conference Phone User Manual


 
Administrator’s Guide for the VSX Series
2 - 32
Connecting Control and Accessibility Equipment
The VSX 5000, VSX 7000, and VSX 7000s systems provide one RS-232 port; the
VSX 7000e and VSX 8000 systems provide two. You can use the RS-232 serial
ports to:
Connect a modem and use a closed captioning service
Pass data from a device connected to your system to a device connected to
the far site system
Control the system through a touch-panel using the API
Provide control signals for an additional camera
Provide control signals for a Polycom Vortex mixer (VSX 8000)
Connecting Closed Captioning Equipment
The VSX system can receive closed captioning from equipment connected
directly to the RS-232 serial port, or from a captioning service via modem or
VSX Web.
To connect a modem to receive closed captioning:
1. Connect a null modem adapter to the RS-232 serial port.
2. Connect an RS-232 cable to the modem and to the null modem adapter.
3. Connect the modem to a phone line.
You may need to configure the modem to answer automatically. You may also
need to configure it to ignore DTR signals.
You must set the baud rate of the RS-232 serial port and the modem to the same
speed. You will also need to configure the RS-232 serial port for Closed
Caption. Refer to Configuring for Use with a Modem on page 4-30.
Connecting Touch-Panel Controls
You can connect an AMX or Crestron control panel to the system’s RS-232
serial port as part of a custom room installation. You will need to program the
control panel. Refer to the Integrator’s Reference Manual for the VSX Series for
information about the API commands.
You will need to configure the RS-232 equipment according to the manufacturer’s
instructions, and you will need to configure the RS-232 serial port on the system
exactly the same way.