CHAPTER 6. INSTALLING INTEL DIALOGIC BOARDS 6-19
To configure the BCP connection panel
1. Use the slide switch on the top of the BCP connection panel to set the Mode of
Operation to Watchdog mode.
2. Connect a serial cable from the COM port on the PC to the RS-232
Watchdog Signal
port on the BCP connection panel.
The cable transmits a periodic watchdog signal from TeleVantage to the BCP
connection panel.
3. Set at least one of the
Watchdog Signal Type switches on the BCP connection panel
to the On position. More than one of the switches can be on.
Where to go next_______________________________________
When you have successfully installed Intel Dialogic and Toshiba hardware, and prepared your
PC for the Intel Dialogic SR 5.1.1 installation as described in this chapter, go to Chapter 7.