Vertical Communications TeleVantage 7.5 IP Phone User Manual


 
CHAPTER 6. INSTALLING INTEL DIALOGIC BOARDS 6-13
Connecting HDSI/x analog station boards
HDSI/x boards include an external station interface box (SIB) which provides the analog
interface for station activity.
The SIB sits between the HDSI/x board and the Intel Dialogic Business Communications
Platform (BCP) connection panel or breakout box. All connections are on the back of the SIB:
Note:
The maximum distance that the SIB can be from the HDSI/x board is 660 feet (201
meters.)
1. Connect the board to the SIB using the 4 RJ-45 cables. Connect the top port of the
installed board to the left-most port on the back of the SIB, and so forth.
Note:
Cables must be connected in the correct order. If they are not connected
correctly, TeleVantage stations will be numbered incorrectly. Also, stations may not be
detected when you start the TeleVantage Server. See TeleVantage Server fails to
detect some or all stations on HDSI/x analog station board on page C-3.
2. Do one of the following:
Connect the SIB to the BCP via the 5 RJ-21X ports on the back of the SIB. Be sure
to use an MSI -R power supply to power the BCP Panel so that it doesnt go into
failover mode until power is out.
Connect the SIB to the breakout box using an RJ-21X connector.