Chapter 6 Diagnostics Vmux-2100 Installation and Operation Manual
6-2 Tone Injection
Diagnostics
1. Inject Tone Test
2. Local Loop Test
3. Remote Loop Test
4. Display Active test
5. Ping
@ - Db Update; # - Db Undo
ESC-prev.menu; !-main menu; &-exit
Figure 6-2. Diagnostics Menu
2. From the Diagnostic menu, choose Inject Tone Test.
The Inject Tone Test menu appears (see Figure 6-3).
Inject Tone Test
1. Slot > (Slot 1)
2. Port > (Port 1)
3. Timeslot [1 - 31] (1)
4. Direction > (Local)
5. Time Out(seconds, 0=forever) [0 - 60]... (0)
6. Activate
@ - Db Update; # - Db Undo
ESC-prev.menu; !-main menu; &-exit
Figure 6-3. Inject Tone Menu
3. From the Inject Tone Test menu, perform the following steps to complete the
tone injection activation:
Select a desired slot.
Select a desired E1/T1.
Select a timeslot for the tone injection.
Specify direction of the tone injection:
Local (towards the local PBX, see Figure 6-1)
Define the tone injection timeout (period of time after which the tone
injection stops automatically):
0 seconds (forever) to 60 seconds
Activate the tone injection by typing 6, and selecting Yes from the
displayed menu.
Repeat the procedure for all timeslots that you intend to test.
You can display information on all tests running at a time by selecting Display Active
Tests from the Diagnostics menu.
Note