RAD Data comm Vmux-2100 IP Phone User Manual


 
Chapter 4 Management from a Terminal Vmux-2100 Installation and Operation Manual
4-12 Configuring the Vmux-2100 System
Configuring the Control Port
Vmux-2100 allows you to configure the baud rate, timeout period, and
connection of a dial-in modem to the rear panel CONTROL port.
Configuring the Data Rate
The Vmux-2100 control data port supports baud rates in the range of 9.6 to
115.2 kbps.
To configure the baud rate:
3. From the System menu (see Figure 4-5), choose Control Port.
The Control Port menu appears (see Figure 4-14).
Control Port
1. Set Baud Rate (bps) > (9600)
2. Timeout (minutes) [3 - 10]... (10)
3. Dial-In Modem > (Disable)
Please select item <1 to 3>
@ - Db Update; # - Db Undo
ESC-prev.menu; !-main menu; &-exit
Figure 4-14. Control Port Menu
4. Choose Set Baud Rate from the Control Port menu.
5. Select a new baud rate from the Set Baud Rate menu.
Configuring the Timeout
The timeout specifies a time interval after which Vmux-2100 automatically
disconnects from the supervisory terminal if no input from the user is detected.
The timeout can be set for between 3 to 10 minutes.
To configure the timeout:
1. From the Control Port menu, choose Timeout.
2. Enter the desired number of minutes and press <Enter>.
Enabling/Disabling Dial-in Modem Access
A dial-in modem can be connected to the CONTROL port for remote
management.
To enable or disable dial-in modem connection via the CONTROL port:
1. From the System menu (see Figure 4-5), choose Control Port.
The Control Port menu appears (see Figure 4-14).
2. From the Control Port menu, choose Dial-In Modem.
The Dial-In Modem menu appears.