2.1 Site Requirements and Prerequisites
AC-powered Vmux-2100 units should be installed within 1.5m (5 ft) of an
easily-accessible grounded AC outlet capable of furnishing the voltage in
accordance with Vmux-2100 nominal supply voltage.
DC-powered Vmux-2100 unit requires a -48 VDC power source, which must be
adequately isolated from the main supply.
The trunk circuit which supplies power to the unit must be protected by a circuit
breaker of 16A maximum.
Allow at least 90 cm (36 in) of frontal clearance for operating and maintenance
accessibility. Allow at least 10 cm (4 in) clearance at the rear of the unit for signal
lines and interface cables.
The ambient operating temperature of Vmux-2100 is 0 to 50°C (32 to 122°F), at a
relative humidity of up to 90%, non-condensing.