RAD Data comm Vmux-2100 IP Phone User Manual


 
Vmux-2100 Installation and Operation Manual Chapter 3 Operation
Default Settings 3-3
3.3 Default Settings
Vmux-2100 is managed by an ASCII terminal or PC running a terminal emulation
program via menu-driven embedded software. Table 3-3 lists the default settings of
the Vmux-2100 configuration parameters.
Table 3-3. Vmux-2100 Default Settings
Parameter Default Value
System
Set Host IP address 0.0.0.0
Set Subnet Mask 0.0.0.0
Set Default Gateway 0.0.0.0
Trap public
Read public
Write private
Managers list 0.0.0.0
Telnet Enable
Set Baud Rate 9600
Timeout 3
Dial-In Modem Disable
A B C D
Idle 1 0 0 0
Signaling Profile
OOS 1 0 0 0
SS7 Keep-Alive Suppression Rate 0% - No Suppression / Not SS7
Hub
Slot 1 NO CARD
Slot 2 NO CARD
Slot 3 NO CARD
Slot 4 NO CARD
Main Link (Lan Parameters)
Set Auto Negotiation Enable
Set Max Capability 100BaseT full duplex
Main Link (E1 Parameters)
Connect No
Frame 732S
Restoration Time 1 second
Clock Source Lbt
Interface Type Ltu
Idle Code ff