RAD Data comm Vmux-2100 IP Phone User Manual


 
Vmux-2100 Installation and Operation Manual Chapter 4 Management from a Terminal
Configuring Main Link and Voice E1/T1 Ports 4-31
7. From the Time Slot Configuration menu, configure the following parameters:
Define timeslot(s) to configure by choosing Update from Time Slot to
select the first timeslot and then choosing To Time Slot to select the last
timeslot.
Select a timeslot type by choosing Type:
N.C. (timeslot is not connected)
Voice (timeslot transmits voice)
HDLC (timeslot transmit data, for example, signaling information).
Assign a timeslot to a bundle by choosing Bundle, and selecting a bundle
number.
Specify a destination port by choosing Destination Port ID, and entering a
port number.
Define the destination timeslots to which the local timeslots are routed. You
only have to specify a starting timeslot; (the rest of the destination timeslots
are configured automatically according to the number of timeslots
previously set by the Update from Time Slot/To Time Slot parameters).
Save the changes that you made to the timeslots by choosing Update Time
Slot.
Make sure to save the changes that you have made to the timeslot configuration.
8. Check the resulting timeslot configuration by choosing Display Time Slots
from the Distribution Of Framer Time Slots menu (see Figure 4-37).
The Display Time Slots screen appears (see Figure 4-39).
Display Time Slots
Ts# Type Bundle Dest Port Dest Ts
1 N.C 0 1 0
2 Voice 1 4 1
| 3 Voice 1 4 2
v 4 Voice 1 4 3
5 Voice 1 4 4
6 N.C 0 1 0
7 N.C 0 1 0
8 N.C 0 1 0
9 N.C 0 1 0
10 N.C 0 1 0
>
@ - Db Update; # - Db Undo
ESC-prev.menu; !-main menu; &-exit
Figure 4-39. Display Time Slots Screen
Note