Lucent Technologies Release 3 Telephone User Manual


 
Using the Change Extensions Command
B-12 Issue 1 June 2000
Release the Voice Ports
Release the voice ports as follows:
1. Starting at the Lucent INTUITY Administration menu, select:
The system responds with the Diagnose Voice Equipment screen, as
shown in Figure B-6.
NOTE:
Ports will be in the manually-out-of-service (Manoos) state if you are
installing a new card or if the ports are busied out. These will
transition to in-service (Inserv) when they are released if the port
detects loop current. If released ports transition to or remain
facility-out-of-service, the ports are not detecting any loop current.
Figure B-6. Diagnose Voice Equipment Screen
2. Press (Change Keys) to display the diagnose function keys.
3. Press (Release) to display the screen showing the Release of Voice
Equipment screen.
The system responds with the Release of Voice Equipment screen, as
shown in Figure B-7.
> Voice Board Diagnostics
> Diagnostics
> Customer/Services Administration
F8
F3