Channel Mapping
A-6 Issue 1 June 2000
2. Verify that all of the channels that are listed are in the in-service (Inserv)
state. This state is listed in the State column of the display. Use either the
up and/or down arrow keys to scroll through the channel listings, or use
the (Previous Page) and (Next Page) keys.
3. Continue with Assign Service to Channels for Testing on the next page. If
you need to make any changes to any channel states, continue with this
procedure.
4. Press (Cancel) twice to reach the INTUITY Administration menu.
5. Starting at the INTUITY Administration menu, select:
The system responds with the Diagnose Voice Equipment screen, as
shown in Figure A-5.
NOTE:
Ports will be in the manually-out-of-service (Manoos) state if you are
installing a new board. These will transition to in-service (Inserv)
when they are released if the board detects loop current. If released
ports transition to or remain facility-out-of-service, the ports are not
detecting any loop current.
Figure A-5. Diagnose Voice Equipment Screen
F2 F3
F6
> Voice Board Diagnostics
> Diagnostics
> Customer/Services Administration