Lucent Technologies Release 3 Telephone User Manual


 
Conversion Instructions
Issue 1 June 2000
2-45
18. Verify that the message on the screen reads:
Day Date Time
Alarm origination test successful.
The entry on the screen should correspond with the time that you sent the
alarm.
If the test does not complete successfully, complete the following before
contacting your remote maintenance center:
a. Wait a few more minutes and check the test results again. If the test
still reports that it is in progress, continue with Step b.
b. Check the telephone number for the remote maintenance center on
the Alarm Management screen. If this is wrong, the test will not
complete.
c. Verify that the telephone is connected to the modem or RMB. If the
line has problems, the RMB can remain in the testing state, waiting
for the remote maintenance center to answer.
19. Press (Cancel) four times until you reach the Lucent INTUITY
Administration menu.
20. Continue with Task 23, Create a Test Alarm.
Task 23 - Create a Test Alarm
Use the following procedure to create a test alarm. This alarm sends a request to
the remote maintenance center to update their database, and places a minor
alarm on the system.
1. Starting at the Lucent INTUITY Administration menu, select:
The system displays the AUDIX Administration screen (Figure 2-26).
F6
> AUDIX Administration