Cisco Systems WRP400 Telephone Accessories User Manual


 
Basic Administration and Configuration
Upgrading, Rebooting, and Resyncing Your ATA Device
ATA Administration Guide 43
2
NOTE If the value of the
Upgrade Enable
parameter in the Provisioning page is No, you
cannot upgrade the ATA device even if the web page indicates otherwise.
The syntax of the Upgrade URL is as follows:
http://spa-ip-addr/admin/upgrade?[protocol://][server-name[:port]][/
firmware-pathname]
Both HTTP and TFTP are supported for the upgrade operation.
If no
protocol
is specified, TFTP is assumed. If no
server-name
is specified, the
host that requests the URL is used as
server-name
.
If no port specified, the default port of the protocol is used. (69 for TFTP or 80 for
HTTP)
The
firmware-pathname
is typically the file name of the binary located in a
directory on the TFTP or HTTP server. If no
firmware-pathname
is specified,
/
spa.bin
is assumed, as in the following example:
http://192.168.2.217/admin/upgrade?tftp://192.168.2.251/spa.bin
Resync URL
The Resync URL lets you force the ATA device to do a resync to a profile specified
in the URL, which can identify either a TFTP, HTTP, or HTTPS server. The syntax of
the Resync URL is as follows:
http://spa-ip-addr/admin/resync?[[protocol://][server-name[:port]]/profile-
pathname]
NOTE The SPA resyncs only when it is idle.
If no parameter follows
/resync?,
the Profile Rule setting from the Provisioning
page is used.
If no
protocol
is specified, TFTP is assumed. If no
server-name
is specified, the
host that requests the URL is used as
server-name
.
If no port is specified, the default port is used (69 for TFTP, 80 for HTTP, and 443
for HTTPS).