Toshiba DK424I Telephone User Manual


 
System & Station
Program 17 DID/Tie Line Options
Strata DK Programming 5/00 3-53
System & Station
Program 17 DID/Tie Line Options
Processor Type: DK40i, all RCTUs and BCUs
Program Type: System
Initialized Default: LED 01/02 Off, LED 03/04 On
Program 17 Overview
Program 17 assigns lines for Tie and DID operation.
Important! When normal Tie/DID lines are configured with Program 71 and 72 DNIS
assignments, turn LED 05 On and LED 06, 07 and 08 Off for those lines - then
program the lines as required in Programs 71 and 72.
Notes
Each REMU, PEMU, RDDU or TDDU PCB reduces the station port capacity by four station
ports, each RDTU Tie/DID line channel reduces the systems station port capacity by one port.
Always install Tie or DID line PCBs in slot numbers that are higher than station PCB slot
numbers (see Chapter 2 DK40i Configuration in the Strata DK I&M Manual).
Incoming Tie line calls camp-on only if Program 71 assignments are used.
Copy one record sheet for each group of Tie/DID lines that have different Program 17
parameters.
LEDs 09, 10 and 14~20
Not used at this time.
   6SNU +ROG 6SNU +ROG 6SNU +ROG 6SNU +ROG
Line Numbers:
LED/Button X LED On LED Off
09, 10, and
14~20
Not used at this time.
08 DID/Tie line DTMF digits with
tones DID/Tie line DTMF digits without tones
07 DID/Tie line receives ANI and routes per Programs 71 and 72
DID/Tie line does not receives ANI (DID Program *09 and
Tie Program 04)
06 Telephone LCD priority is ANI Telephone LCD priority is DNIS
05
DID/Tie line routes per DNIS assignments:
(Programs 71 and 72)
DID/Tie line routes per Non-DNIS assignments:
(DID Program *09 and Tie Program 04)
04 DID/Tie no second dial tone DID/Tie second dial tone
03 DID line Auto Camp-on busy DID line no Camp-on busy
02 Wink Start for Tie or DID Immediate Start for Tie or DID
01
Page and Voice Announce on incoming Tie line Page access for
Tie/DID DNIS lines
No Page and Voice Announce on incoming Tie line No
Page access for Tie/DID DNIS lines
Enter Line No. that will be DID or Tie line.
To add a port range, enter XXXXXX (low port high port).
Light LED Buttons 01~08 as noted in table below