System & Station
Program 71 DNIS
Strata DK Programming 5/00 3-155
System & Station
A DNIS and/or Tie/DID extension number and/or ANI only line can be assigned to route one of
the following destinations:
Primary Directory Number [PDN] - secondary appearances of this [PDN] will also ring if
Programmed to ring in Program *71, *72, and/or *73
Phantom Directory Number
Distributed Hunt Group
ACD Group
Outside telephone number routed externally over the Public Telephone Network
The system remote maintenance modem
Night ringing over the external page
The external voice paging system (Private Network Tie lines only)
A DNIS number or ANI only line can be assigned to route to one destination only in each of the
three system ringing modes (Day, Day2 and Night); the destination can be unique or different in
each ringing mode. For each DNIS Tie/DID extension number, the routing destination can be a
unique destination or it can be the same destination as that assigned to other DNIS numbers. To
assign lines that receive both ANI and DNIS with each call to Program 71-1 assignments: Program
17, LED 05, 07 and 08 must be turned On; for lines that receive DNIS digits only, LED 05 and 08
must be On.
This program can also be used with non-DNIS or non-ANI Tie and/or DID lines to route calls. In
this case, the normal Tie digit assignments in Program 04 and DID digit assignments in Program
*09 will not be active - Program 17, LED 06, 07, 08 must be Off and LED 05 must be On for
normal Tie/DID lines.
The last address in Program 71-0 is used to assign ANI only lines to a routing destination (see
Table 3-9).
Table 3-9 DNIS Addresses
All ANI only lines must be assigned to the same routing destination; this destination can be unique
in each of the ringing modes (Day/Day2/Night).
To assign an ANI only Tie/DID line to Program 71-1 assignments: Program 17, LED 05 must be
turned Off and LED 07 and 08 must be On for lines that receive ANI digits only.
Program 71-4 Overview
This feature is available when using DTMF In-band VM integration only; it is not provided with
SMDI VM integration.
This Program assigns a Voice Mailbox ID (VMID) number to each DNIS/Tie/DID extension
number and/or ANI only lines. This allows each DNIS/Tie/DID extension number and/or ANI
only lines to be routed to a unique Voice Mail box when the number directly rings or is Call
Forwarded to the Voice Mail system. When a DNIS/Tie/DID extension number or ANI line rings a
station that has call forwarding set to Voice Mail, the DNIS/Tie/DID extension or ANI VMID is
sent to the VM machine (if programmed in Program 71-4). If a DNIS/Tie/DID extension or ANI
VMID is not programmed, the Call Forwarding stations VMID is sent to the voice mail machine
Address Processor
499 RCTUC3/D3, RCTUE3/F3, B2CAU/BU, B3CAU/BU, B5CAU/BU
349 RCTUBA3/B3, B1CAU
199 RCTUA3 or DK40i