System & Station
Program *10 – Enhanced 911 Operation
3-42 Strata DK Programming 5/00
Program *10 – Enhanced 911 Operation
Processor Type: DK14, DK40i, all RCTUs
Program Type: System
Initialized Default: See each program
Program *10 provides two QSTU2, RSTU, KSTU2, RDSU, PSTU, or PESU ports to be assigned
to interface with central office E911 trunks.
E911 enhanced operation provides locator information to the responding agency to provide more
complete name and address information, including building, floor, etc. This is done by sending the
station number of the 911 caller to the E911 emergency center. This locator information is then
cross referenced with name/number/address data in the E911 central database, and the E911
operator receives the precise location along with the basic information.
The Strata DK14, DK40i and DK424 accomplishes this through a special interface between the
KSU and the CO. This special interface takes the station number information and sends it through
the public network in a format compatible with the central E911 database. This special interface is
required in addition to sending software within the Strata DK.
The required interface is an external device (Telident or Proctor) that interfaces to up to two
standard analog station ports.
Figure 3-1 Physical Connection of E911 Interface
Programs *10-11 and *10-12 – E911 Standard Telephone Ports Assignment
Initialized Default: Blank
✱ ✱ ✱ ✱6SNU✱ +ROG 6SNU +ROG 6SNU +ROG 6SNU +ROG
Tip/Ring E911 CKT #1 CAMA Trunk #1
Strata DK
Proctor or
Telident
E911 Interface
Central
Office
E911
Center
KSTU2
QSTU2
RSTU
RDSU
PESU
CAMA Trunk #2Tip/Ring E911 CKT #2
1687
E911 CKT 1 and 2 assigned in Program
*
10
First E911 Port = 11
Second E911 Port = 12
E911 RSTU/KSTU2 Port Number
E911 RSTU/KSTU2/QSTU2 Port Number
First Standard Port