Toshiba DK424I Telephone User Manual


 
System & Station
Program 15 Ground/Loop/Tie/DID Line Options
Strata DK Programming 5/00 3-47
System & Station
Program 15 Ground/Loop/Tie/DID Line Options
Processor Type: DK14, DK40i, all RCTUs and BCUs
Program Type: System
Initialized Default: All LEDs are Off
   6SNU +ROG 6SNU +ROG 6SNU +ROG 6SNU +ROG
Processor Type CO Line Range Processor Type CO Line Range
DK14 001~004 B1CU 001~032
DK40i 001~012 B2CAU/BU 001~120
RCTUA 001~016 B3CAU/BU 001~120
RCTUBA/BB 001~048 B5CAU/BU 001~200
RCTUC/D 001~144
RCTUE/F 001~200
Program Code
Program LED On LED Off
Line
LED
01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20
0
CPC on AR VM
Calls and Voice
Calls
Detect Ignore
1
CO/DID/Tie Line
Signal
DP DTMF
2
CO/DID/Tie Dial
Pulse Rate
(Pulse per sec.)
20 PPS 10 PPS
3
AR Hold Detect Ignore
4
AR Timing
Crossbar
95 msec.
ESS
(electronic)
450 msec.
5
Tandem CO Line
Connection with
Station Dropout
Enabled
Not
Enabled
7
Forced Account
Code
Enabled
Not
Enabled
8
Operation After CO
Line Flash
No DTMF
receiver
After Flash
DTMF
receiver
After Flash
SELECT = Program Code
Press
6FUROO to advance or 3DJH to go
back.
To advance the CO line range, press
6FUROO
located beneath the LCD. Press
3DJH for a
lower range.
LED Buttons = CO line
Specify CO line by setting LEDs as defined by the
table below. When you are finished, all LEDs with
an X should be lit.