System & Station
Program *03 for DK424 – Cabinet Type Identification
3-12 Strata DK Programming 5/00
Program *03 for DK424 – Cabinet Type Identification
Processor Type: RCTUE/F or B5CAU/B5CBU
Program Type: System
Initialized Default: All cabinets = 1
Program *03 - Overview
You must run this program when using the DK424 or DK280 RCTUE/F, or DK424i B5CAU/BU.
It identifies which type of cabinets are installed (DK424i, DK424 or DK280).
The RCTUE/F processor can be installed in a DK424 or DK280 base cabinet. The expansion
cabinets can be any combination of DK424 and DK280 - except the seventh expansion cabinet
must be a DK424.
The DK280 expansion cabinet can only support six universal PCB slots in any possible
configuration.
The DK424 expansion cabinet supports eight universal PCB slots only if the RCTUE/F is installed
in a DK424 base cabinet and the MBJU jumper is removed from the DK424 base cabinet
backplane. MBJU does not apply with DK424i cabinets.
Important! This programs exists on DK424i B5CAU/BU processors. It must always be set to
Cabinet Type “1” allowing 10 slots for each DK424i Expansion Cabinet. DK280
and DK424 Expansion Cabinets cannot be used with DK424i processors.
✱ ✱ ✱ ✱6SNU✱ +ROG 6SNU +ROG 6SNU +ROG 6SNU +ROG
SELECT =
(Cabinet No. 1~7)
Cabinet Type
(1 or 2)
1 (Base)
2 (1st Expansion)
3 (2nd Expansion)
4 (3rd Expansion)
5 (4th Expansion)
6 (5th Expansion)
7 (6th Expansion) 1 only
SELECT = Cabinet No. (1~7)
CABINET = 1 or 2 (type)
Type 1 (DK424 or DK424i)
Type 2 (DK280)
Turn System Power Off (5 sec) then On.
or...
Run Program 91-2
Expansion Cabinet Universal PCB Slot Availability
Case 1
RCTUE/F in DK424 Base Cabinet with MBJU removed
Note
MBJU is not used with DK424i cabinets.
Case 2
RCTUE/F in DK280 Base Cabinet
Expansion Cabinet (max 6) Universal PCB Slots
DK424 1~8 available
DK280 1~6 available
Expansion Cabinet (max 5) Universal PCB Slots
DK424 1~6 available