Toshiba DK424I Telephone User Manual


 
Glossary
RCOU ~ RPSU280
GL-8 Strata
RCOU CO Line Interface UnitAn optional PCB that provides the system with four loop start CO
lines. An optional RCOS subassembly can be attached to the RCOU for four more loop start
analog CO lines. Supports Caller ID when used with RCIU/RCIS circuits.
RCTU Common Control UnitThe systems controller PCB that contains the system's main
microprocessor and microprocessor bus, ROM, RAM, time switch logic, busy tone detectors,
system tones and MOH/BGM Interface. RCTUs include: RCTUA, RCTUB, RCTUBA/BB,
RCTUC/D, and RCTUE/F. Each RCTU supports different station and line capacities. The
RCTU PCBs also provide interface for the optional RRCS PCB and RKYS key.
RDDU Direct Inward Dialing Interface UnitOptional PCB that provides four analog Direct Inward
Dialing line circuits. Supports ANI and DNIS.
RDSU Digital/Standard Telephone Interface UnitOptional PCB that provides two standard
telephone and four digital telephone circuits in its basic configuration. An RSTS can be
attached to the RDSU for two additional standard telephone circuits.
RDTU T1/DS-1 Interface UnitOptional PCB that provides up to 24-digital channels that can
individually be assigned for loop start CO line, ground start CO line, E & M tie line, or DID line
operation. Supports ANI and DNIS.
REMU E & M Tie Line UnitAn optional PCB that provides the system with support for four E & M
Type I or Type II, Immediate or Wink Start tie lines. Supports ANI and DNIS.
RFIF Floor Mount Installation KitKit that is used to floor mount systems.
RGLU Analog Ground/Loop Start CO Line Interface UnitProvides four CO line circuits that can be
individually configured for loop start or ground start CO line operation. Supports Caller ID
when used with RCIU/RCIS circuits.
RKYS Feature Key UpgradeSubassembly that attaches to the common control unit to provide the
system with optional features. There are four versions of the RKYS: the RKYS1, the RKYS2,
the RKYS3 and the RKYS4, each of which provides a distinct set of features.
RMDS Remote Maintenance Modem SubassemblyA subassembly installed on the RSIU Optional
Interface Unit that allows the system to be connected with a remote administration/
maintenance terminal or DK Admin/DK Backup personal computer.
RPCI-DI Computer Data Interface UnitReplaces the normal telephone base and provides all the
functions of PDIU-D12. In addition, it can be switched to a second mode automatically and
used with a Telephone Application Program Interface (TAPI) software application.
RPTU ISDN Primary Rate Interface (PRI) UnitProvides 1 data (control) channel and 23 bearer
channels.All B-channels appear and program as CO lines in the DK424 system and can be
individually configured for local service, FX, WATS, DID, tie, etc., service operation.
Supported by the RCTUBA3/BB4, RCTUC3/D4 and RCTUE3/F4.
ROM Read Only MemoryRefers to the type of system memory that holds static software that
comprises the mechanics of the features functions. ROM is only revised by Toshiba software
engineers.
RPSB (1 and 2) Power StripInterface between cabinet power supplies and the commercial AC power
source. The RPSB provides outlets for three power supplies. One RSPS is required for
systems with three or four cabinets, two or three RSPSs for five- or six-cabinet systems.
RPSU280 Cabinet Power SupplyFurnishes power to all of the stations and peripherals connected to
the cabinet PCBs. Each Base and optional expansion cabinet has a separate power supply.
Term Definition