Panasonic KX-TVS80 Telephone User Manual


 
B6 SYSTEM ADMINISTRATION - SYSTEM PARAMETER SETTINGS
236
SYSTEM ADMINISTRATOR'S GUIDE
Other Parameters - Dialing Parameter
To select Dialing Parameter, follow the menu path as shown:
System Administration Top Menu - 1 - 5 - 7 - 2
Table 55
Parameter Value Range
(Default)
Description/Function
Number of
Digits
to Access
Outside Line
0-8 digits
(1)
Specifies the number of digits necessary to access an
outside line.
Example:
If the PBX requires callers to dial "9" to access an
outside line, this parameter should be set as "1." This
enables the system to recognize that an outgoing call
setup sequence is completed once the initial "9" has
been dialed (9-123-4567). The full sequence is
therefore: 9 - (outgoing call setup sequence) - 123-
4567.
The VPS can discriminate between local and long
distance calls and can report outgoing calls and calling
times for billing purposes on periodic port usage
reports.
Call Transfer
No Answer
Time
10-60 s
(20)
Specifies the amount of time that the VPS must wait
before retrieving the transferred call when there is no
answer at the destination extension.
Outgoing Call
No Answer
Time
10-90 s
(30)
Specifies the amount of time that the VPS must wait
before concluding that there is no answer at the outside
number called.
Pause Time 1-9 s
(2)
Specifies the pause time between dialed digits.