Panasonic KX-TVS80 Telephone User Manual


 
7.2 UTILITY COMMANDS
SYSTEM MAINTENANCE AND TROUBLESHOOTING
139
Error and Warning Indications During System Operation
7.2.7 Saving the System Data to the Backup Device (SAVE)
All system programming data and voice prompts can be saved in separate data files. To save
this data, a data terminal must be connected to the RS-232C port of the VPS. Files must be
saved individually. The SAVE command must be executed for each data file. It will require
SYSTEM ERROR: 2 Error loading of report data.
SYSTEM ERROR: 3 Clock error.
SYSTEM ERROR: 4 Mailbox data error.
SYSTEM ERROR: 5 Message data error (1).
SYSTEM ERROR: 6 Message data error (2).
SYSTEM ERROR: 7 Error loading of control data.
SYSTEM ERROR: 8 Error loading of voice prompt data.
SYSTEM ERROR: 9 Error loading of MWL control data.
SYSTEM ERROR: 10 Error loading of flash memory identify data.
SYSTEM ERROR: 11 Error writing of VBI chain data.
SYSTEM ERROR: 12 Error writing of BLK chain data.
SYSTEM ERROR: 13 Error loading of user prompt modify data.
SYSTEM ERROR: 14 Error loading of Class of Service data.
No CO lines are active!! No Port cards present.
COs are all disabled!! All Ports are malfunctioning.
APT(DPT) Interface Connection is not
Established.
Ports are malfunctioning for APT(DPT)
Integration because telephone lines are
disconnected or Integration with PBX is not set to
APT(DPT) Integration mode.
Table 29
Indication Meaning
FLASH MEMORY STORAGE SPACE IS
NOW EXCEEDING
80%...
80% or more of the Flash Memory voice
message save area is used.
ASCII TERMINAL program Load Error Error loading of ASCII terminal control
program.
Table 28