ClearOne comm SR 1212 Conference Phone User Manual


 
27
Converge Pro TH20 Rear Panel
VOLTAGE RANGE 100-240 VAC 2A
FREQUENCY 50Hz / 60Hz
12 12
LINE IN LINE OUT
LINK IN
LINK OUT
RS-232
CONTROL / STATUS
A
B
PC
LAN
TELCO
LINE
SET
1457896
11
Converge Pro SR1212 Rear Panel
VOLTAGE RANGE 100-240 VAC 2A
FREQUENCY 50Hz / 60Hz
MIC / LINE
12341234
LINE IN
LINE OUT
9101112
LINE OUT
9101112
56785678
+-
LINK IN
LINK OUT
RS-232
CONTROL / STATUS
A
B
PC
LAN
123457896
1110
Converge Pro SR1212A Rear Panel
LINE IN
LINE OUT
5 6 7 8
1
10
12
2 3 4 6
7
8
1 2 3 4 1 2 3 4
5 6 7 8
5 6 7 8
9
,
R
Converge Pro Rear Panel Connectors
AC Power1. : IEC connector, 100 – 240VAC auto-adjusting, 50/60Hz.
Warning: This equipment must be connected to an AC mains socket outlet with a protective earthing
connection. The third prong of this connector (ground) is an important safety feature. Do not attempt to
disable this ground connection by using an adaptor or other method.
Mic/Line Inputs2. : Mini-terminal push-on block connector for any combination of microphone and/or line level
inputs. (Converge Pro 880: 8 inputs. Converge Pro 880T: 8 inputs. ConvergePro 880TA: 8 inputs. Converge
Pro 840T: 4 inputs. Converge Pro 8i: 8 inputs. Converge Pro TH20: 0 inputs. Converge SR 1212: 8 inputs.
Converge SR 1212A: 8 inputs.)
Line Outputs3. : Mini-terminal push-on connector for line-level outputs (880, 880T, 880TA, 840T, SR 1212, SR
1212A).
Line Inputs4. : Mini-terminal push-on block connector for line level inputs only. (Converge Pro 880: 4 inputs.
Converge Pro 880T: 4 inputs. Converge Pro 880TA: 4 inputs. Converge Pro 840T: 4 inputs. Converge Pro 8i: 4
inputs. Converge Pro TH20: 2 inputs. Converge SR 1212: 4 inputs. Converge SR 1212A: 4 inputs.)
Line Outputs5. : Mini-terminal push-on block connector for line-level outputs (880, 880T, 840T, TH20, SR1212).