ClearOne comm SR 1212 Conference Phone User Manual


 
258
PAFLT – PA Fault
This indicates one of the power amplifier channels is in a FAULT condition. This is Read-Only, and is
automatically generated if a fault occurs.
Command Form: DEVICE PAEQEN [Bitmap]
Argument Type Size Values
Bitmap Hexadecimal Integer 4
PAIMPED – PA Output Impedance
This command selects the output impedance for the PA channel to be either 8 ohms or 70/100V.
Command Form: DEVICE PIAMPED <Channel> <Group> [Value]
Argument Type Size Values Units
Channel Channel 1 See Groups and Channels
Group Group 1 23 (J)
Value Unsigned
Short
2 0 = 8 ohms
1 = 70/100V
(Null to query in text)
PALEN – PA Limiter Enable
This command changes enables the Limiter on a power amplifier channel.
Command Form: DEVICE PALEN <Channel> <Group> [Value]
Argument Type Size Values Units
Channel Channel 1 See Groups and Channels
Group Group 1 23 (J)
Value Unsigned Short 2 0 = Off
1 = On
2 = Toggle
(Null to query in text)
PALT – PA Limiter Threshold
This command sets the Limiter threshold on a power amplifier channel.
Command Form: DEVICE PALT <Channel> <Group> [Value]
Argument Type Size Values Units
Channel Channel 1 See Groups and Channels
Group Group 1 23 (J)
Value Signed Float 2 -65.00 to +20.00
(Null to query in text)
dB