ClearOne comm SR 1212 Conference Phone User Manual


 
254
MTRXLVL – Matrix Attenuation Adjust
This command selects/reports the matrix level at the cross point.
Command Form:
DEVICE MTRXLVL <Src. Ch.> <Src. Gp.> <Dest. Ch.> <Dest. Gp.> [Value] [A/R]
Argument Type Size Values Units
Source Channel Channel 1 See Groups and Channels
Source Group Group 1 1, 3, 5, 6, 7, 12, 17
(I, M, P, E, L, F, R)
Destination Channel Channel 1 See Groups and Channels
Destination Group Group 1 2, 5, 6, 12, 16,
(H, J, O, P, E, F, T,)
Value Signed Float 4 -99.00 – 99.00 **
(Null to query in text)
dB
Absol / Rel 0 A = Absolute
R = Relative
Null = Relative
NOTE: Values indicate entry range only. Actual internal range of the matrix attenuation is from –60
to +12dB, and absolute values are limited to the internal gain range.
MUTE – Mute
This command selects/reports the setting of mute on a channel.
Command Form: DEVICE MUTE <Channel> <Group> [Value]
Argument Type Size Values Units
Channel Channel 1 See Groups and Channels
Group Group 1 1, 2, 3, 5, 7, 12, 16, 17 (I, J, O, M, P, L, F, T, R)
Value Unsigned Integer 2 0 = Off
1 = On
2 = Toggle
(Null to query in text)
NAME – Unit Name (NETBIOS Name)
This command sets/reports the name of the unit which is also used for its NETBIOS name.
Command Form: DEVICE NAME [Value]
Argument Type Size Values Units
Value String 16 1 – 15 Characters
(Null to query in text)
NCD – Noise Cancellation Depth Adjust
This command selects/reports the depth setting of the Noise Cancellation.
Command Form: DEVICE NCD <Channel> <Group> [Value]
Argument Type Size Values Units
Channel Channel 1 See Groups and Channels
Group Group 1 3, 17 (M, R)
Value Unsigned Integer 2 6 – 15
(Null to query in text)
dB