ClearOne comm SR 1212 Conference Phone User Manual


 
266
Value Unsigned Short 2 0 = Standard
1 = Custom
(Null to query in text)
RINGOFF – Ring Cadence Off Time
This command sets the ring cadence off time. The country code should be set first using the COUNTRY
command.
Command Form: DEVICE RINGOFF <Channel> <Group> [Value]
Argument Type Size Values Units
Channel Channel 1 See Groups and Channels
Group Group 1 17 (R)
Value Unsigned Short 2 0 = 80
1 = 128
2 = 256
3 = 384
4 = 512
5 = 640
6 = 768
7 = 896
8 = 1024
(Null to query in text)
ms
RINGON – Ring Cadence On Time
This command sets the ring cadence on time. The country code should be set first using the COUNTRY
command.
Command Form: DEVICE RINGON <Channel> <Group> [Value]
Argument Type Size Values Units
Channel Channel 1 See Groups and Channels
Group Group 1 17 (R)
Value Unsigned Short 2 0 = 100
1 = 150
2 = 200
3 = 256
4 = 384
5 = 512
6 = 640
7 = 1024
(Null to query in text)
ms
RXBOOST – Receive Boost
This command selects/reports the receive boost status.
Command Form: DEVICE RXBOOST <Channel> [Value]
Argument Type Size Values Units
Channel Channel 1 See Groups and Channels
Group Group 1 17 (R)
Value Unsigned Integer 2 0, 3, 6, 9, or 12
(Null to query in text)
dB